Kestrel® 4100 Pocket Air Flow Tracker

Kestrel® 4100 Pocket Air Flow Tracker
Price: $489.00 inc GST
Product Code: k4100
Tell a Friend  Tell a Friend
Write review / comment  Write review / comment
We Accept:


Product Options:
Accessories

Quantity: Add to Basket

» Product Information »

HVAC Technician

The Kestrel 4100 is an easy to use, affordable, pocket-sized tool that's ideal for:

  • Facilities managers
  • HVAC equipment sales people
  • Home inspectors
  • Dehumidification specialists
  • Field installers & technicians

See what Kestrel 4100 users had to say >>

The Kestrel 4100 Pocket Air Flow Meter was engineered specifically with the HVAC technician’s many needs in mind. In addition to measuring volume air flow, this multi-functional precision instrument also measures temperature, relative humidity and dewpoint, either ambient or in any accessible airflow.

CFM Without A Calculator

Tired of cumbersome equations to calculate the CFM? The 4100 makes it possible to determine CFM without using a calculator. For immediate and accurate air flow readings, simply enter the duct shape and dimensions, hold the 4100 in the air flow and the volume air flow readings are displayed … no calculator required! The convenient averaging mode ensures accurate CFM readings in any airflow or duct size and shape.

Kestrel 4100

Easy-to-Use Data Logging & Computer Upload

The Kestrel 4100 air flow meter features a powerful data logger that records 2000 sets of measurements at user-selectable time intervals (over 2 years of data can be recorded). Logged data can be reviewed with the 4100’s on-screen graphing capabilities, or uploaded to a PC for in-depth review. The optional Kestrel Interface and accompanying Kestrel Communicator software makes long-term storage, in-depth analysis and detailed charting of stored data a breeze.

With on-screen customization, the 4100 can truly be personalized for every technician. Easy set-up screens allow the unit to display only relevant readings and hide screens not relative to the job. Plus the Kestrel’s user screens group pertinent information on one easily referenced screen.

NIST-Traceable Accuracy

Don’t let the inexpensive price tag fool you — the Kestrel 4100 is as accurate as instruments costing far more. Every Kestrel is individually calibrated to NIST-traceable standards and comes with a free Certificate of Conformity. (Individual NIST certificates and recalibration are also available.) Consider the 4100’s hold and averaging functions, and it’s the only instrument HVAC technicians need to perform a variety of jobs.

Winner of the Dealer Design Award

This all-in-one instrument is so comprehensive, accurate and innovative that it won the ACHR News Dealer Design Award for excellence in product design. "Every technician I employ will have one of these units ASAP!" said one of the Dealer Design judges.

Kestrel 4100 Measures

  • Current, average, and maximum air velocity
  • Volume air flow in cfm, L/s, m³/s, m³/m, m³/h
  • Air Velocity in ft/m, mph, m/s, km/h, kts, Beaufort
  • Temperature in °F or °C
  • Relative humidity in %
  • Heat stress index
  • Dewpoint

Kestrel 4100 Features

  • Waterproof and floats
  • Backlit display for low light conditions
  • Multi-Function 3-line display
  • Humidity sensor can be recalibrated in the field with our Relative Humidity Calibration Kit.
  • Automatic and manual data storage
  • Customizable data storage - 2000 data points
  • Data charting
  • Data upload (with optional interface)
  • Minimum, maximum, and average values
  • Five languages (English, French, Spanish, German, and Italian)
  • User-replaceable impeller
  • Flip-top impeller cover
  • US Patent Nos. 5,783,753 and 5,939,645 and 6,257,074
  • All instruments and accessories are completely assembled in the USA
  • 5-year warranty

Kestrel 4100 Includes

  • Soft carry pouch
  • Wrist and neck lanyards
  • Batteries - 2 AAA
  • Kestrel Certificate of Conformity

Specifications:

Measurement
Response Time
Units Operational Range Resolution Accuracy (+/-) Specification Range
Wind Speed
1 second  
m/s 0.4 to 60.0 m/s 0.1 Larger of 3% of reading or least significant digit 0.4 to 40.0 m/s
ft/min 59 to 11,948 ft/min 1 59 to 7877 ft/min
km/h 1.0 to 218.0 km/h 0.1 1.0 to 144.0 km/h
mph 0.8 to 135.0 mph 1 0.8 to 89.0 mph
knots 0.6 to 118.3 kt 0.1 0.6 to 78.0 kt
Beaufort 0 to 12 B 0.1 0 to 12 B
1 inch diameter impeller with precision axle and sapphire bearings.  Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º.  Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s.  Sustained operation above 60 MPH / 27 m/s will wear impeller rapidly and may cause destruction of impeller.  Replacement impeller (NK PN-0801) may be field-installed without tools (US Patent 5,783,753).
Air Flow
1 second  
cfm 0 to 99,999 cfm 1 3% of reading 0 to 99,999 cfm
m3/h 0 to 99,999 m3/h 1 0 to 99,999 m3/h
m3/m 0 to 99,999  m3/m 1 0 to 99,999  m3/m
m3/s 0.0 to 9,999.9 m3/s 0.1 0.0 to 9,999.9 m3/s
L/s 0 to 99,999 L/s 1 0 to 99,999 L/s
Automatically calculated from Air Velocity measurement and user-specified duct shape (circle or rectangle) and dimensions (units: in, ft, cm or m). Maximum duct dimension input: 258.0 in / 21.5 ft / 655.3 cm / 6.55 m.
Temperature
1 second
°F -49.0 to 257.0 °F 0.1 1.8 °F -20.0 to 158.0 °F
°C -45.0 to 125.0 °C 0.1 1.0 °C -29.0 to 70.0 °C
Measures air, water and snow temperature.  Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645).  Calibration drift negligible.
Relative Humidity
1 minute 
%RH 0.0 to 100.0 % 0.1 3.0 %RH  5.0 to 95.0 % non-condensing
Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074).  (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and must be kept out of direct sunlight.)  Calibration drift +/- 2% over 24 months. Relative humidity may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN-0802).
Wind Chill
1 second  
°F 0.7 to 135.0 MPH, -49.0 to 257.0 °F 0.1 1.8 °F 1.8 to 89.0 mph, -50.0 to 50.0 °F
°C 0.4 to 60.0 m/s, -45.0 to 125.0 °C 0.1 1.0 °C 0.4 to 40 m/s, -45.6 to 10.0 °C
Calculated from the primary measurements of wind speed and temperature.  Utilizes the NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10 m above ground.  (Specification temperature limits established by WCT Tables.)
Heat Index
1 minute  
°F 0.0 to 100.0 %RH, -49.0 to 257.0 °F 0.1 3.6 °F 70.0 to 130.0 °F, 0 to 100% RH
°C 0.0 to 100.0 %RH, -45.0 to 125.0 °C 0.1 2.0 °C 21.1 to 54.4 °C, 0 to 100 %RH
Calculated from the primary measurements of temperature and relative humidity.  Utilizes the NWS Heat Index (HI) tables.  (Specification temperature limits established by HI tables.) 
Dewpoint
1 minute  
°F 0.0 to 100.0 %RH, -49.0 to 257.0 °F 0.1 3.6 °F -20.0 to 158.0 °F, 20.0 to 95.0% RH
°C 0.0 to 100.0 %RH, -45.0 to 125.0 °C 0.1 2.0 °C -29.0 to 70.0 °C, 20.0 to 95.0 %RH
Calculated from the primary measurements of temperature and relative humidity. Temperature to which the air would need to be cooled at a constant pressure to become saturated.
Wet Bulb Temperature
1 minute  
°F -49.0 to 257.0 °F, 0.0 to 100.0 %RH, 8.86 to 32.48 inHg 0.1 3.6 °F 32.0 to 100.0 °F, 5.0 to 95.0% RH, 8.86 to 32.48 inHg, <19700 ft
°C -45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa 0.1 2.0 °C 0.0 to 37.8 °C, 5.0 to 95.0 %RH, -2000.0 to 9000.0 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Temperature indicated by a wet bulb psychrometer.
Max/Avg Wind Speed (Air Velocity),
Crosswind, Headwind/Tailwind
One-button clear and restart of Max Wind Gust and Average Wind measurement.
Data Storage / Display Minimum, maximum, average and logged history stored and displayed for every measured value. 2000-point data logger with graphical display. Auto data storage; interval settable from 2 seconds to 12 hours. Manual data capture.  
Data Upload Requires optional PC interface (NK PN-0830) and provided software. RS-232 connection with USB adapter available.
Display Multifunction, multi-digit programmable dot-matrix display.
Display Update 1 second.
Display Backlight Choice of aviation green or visible red electroluminescent backlight. Automatic or manual activation.
Clock / Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Operational Temperature Range
(LCD and Batteries)
The operational temperature range of the liquid crystal display and batteries is 14° F to 131° F / -10 °C to 55 °C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to take reading.
Storage Temperature -22 °F to 140 °F / -30 °C to 60 °C.
Auto Shutdown User-selectable:  15 or 60 minutes with no key presses or disabled.
Languages English, French, German, Italian, Spanish.
Certifications CE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge).  
Batteries AAA Alkaline, two, included. Average life, 400 hours of use, +/-depending on backlight use.
Environmental Waterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.).
Dimensions Unit 5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm.
Weight Unit 3.6 oz / 102 g.

Back To Top

Product Code: k4100


About Us | Contact Us | Postage/Frieght | Help | Terms & Conditions | Privacy Policy | Ring Cutter Rescue Tool | Ultimate gear bag | Leatherman Wave | Genfo Firefighting Knapsack | Hooligan Tool by Paratech | Partners | variation_01 | variation_02

Powered by CubeCart